extractor fan for dust

extractor fan for dust

This extractor fan for dust is a dust removal centrifugal fan, so it is suitable for driving wood chips, fibers, dust and other air-containing mixtures. The fan has a plurality of front curved blades, a front plate and a rear cast iron hub. The impeller is dynamically balanced and therefore the air volume is stable. Its main shaft is made of high quality carbon steel.
Product description

Product features:

1. This extractor fan for dust is a dust removal centrifugal fan, so it is suitable for driving wood chips, fibers, dust and other air-containing mixtures. The fan has a plurality of front curved blades, a front plate and a rear cast iron hub. The impeller is dynamically balanced and therefore the air volume is stable. Its main shaft is made of high quality carbon steel.

2. Before installing the extractor fan for dust, check the clearance size of all parts of the fan to ensure that the rotating parts do not touch the fixed parts. When the fan rotates, check the temperature of the bearing after the impeller reaches normal speed. If there is no special requirement for the bearing temperature, it cannot be higher than the ambient temperature by 40 °c. If the fan has a very severe impact and the impact and bearing temperature rises rapidly, stop the fan immediately.

Product maintenance:

Clean internal dust, dirt and other impurities regularly

Check the fan regularly to avoid rusting

Replace the lubricant after turning on the fan. Lubricating oil should be replaced according to actual conditions.

Note:

Since this series of extractor fan for dust has many different machine numbers and parameters, if the data and descriptions we have listed do not meet your needs, please contact us for an introduction or catalog.

Performance and selection:

Non-dimensional performance table and curve for №.10 sample is only given. Other performance is deduced from that.

The calculation formula of non-dimensional performance curve into the dimensional is:

11.jpg

image

22(001).jpg

Fig.1  Non-dimensional performance curve of type C6−48 №10

Table.2  motor conservative factor

Shaft power(kW)

<0.5

>0.5~1

>1~2

>2~5

>5

K value

1.5

1.4

1.3

1.2

1.15

If it is in non-standard state when operating, the performance of non-standard standard state must be converted to the performance of standard state. And then select fan according to the converted performance. The converting formula is as follows: